Hinges: .074" thick, 2" high double spun, full loop, tight pin, five-knuckle hinges, projection welded to door frame and securely fastened to the door with 2 steel rivets. Doors over 42" high shall have three hinges, all other doors shall have two hinges. Finishing: Chemically pretreated metal with a six stage cleaning phosphatizing and metal preparation process. Finish coat shall be hot air-less electrostatically applied enamel baked on at 350 to 400 degrees. Select colors from manufacturer's minimum standard 17 colors. All lockers shall be painted inside and outside with the same color.
Fabrication General
Door Frame:
All door frame members to be not less than 16 gauge formed to a channel shape. Vertical
members to have an additional flange to provide a continuous door strike. Intermembering
parts to be mortised and tenoned and electrically welded together in a rigid assembly
capable of resisting strains. Body: Bolt spacing in locker body construction not to exceed 9" o.c. All locker body components shall be made of cold rolled steel specially formed for added strength and rigidity and to ensure tight joints at fastening points. Tops & bottoms shall be 24 gauge with three sides formed 90 degrees and the front offset formed to be flush with the horizontal frame member. Shelves shall be 24 gauge with four sides formed to 90 degrees, the front edge shall have a second bend. Backs & sides shall be 24 gauge.
Doors: Doors 30" or higher shall be formed from one piece 16 gauge cold rolled sheet steel.
Doors less than 12" wide shall be 18 gauge. Formations shall consist of a full
channel shape on the lock side of adequate depth to fully conceal the lock bar, channel
formation on the hinge side, and right angle formations across the top and bottom. Doors
over 15" wide x 60" & 72" high shall have a 3" wide 20 gauge full
height reinforcing pan welded to the inside face of the door on 6" centers Door Handle 1 & 2 Tier, 2 Person & Duplex: Handle to consist of zinc alloy die-cast case and handle. 40,000 PSI maximum tensile strength chrome plated. Handle to be pulled out to move up latch bar and open door in one motion. Padlock eye for use with 9/32" diameter padlock shackle to be an integral part of handle and to be so located that extension of handle forms a padlock strike. Attachment to latch bar shall be tamper-proof and concealed inside the door. The case shall be kick proof type, shielding and movable part and provide a padlock strike to prevent scratching and marring the door. A lock hole cover plate shall be provided for use with padlocks. Door Latching 1 & 2 Tier, 2 Person & Duplex: Doors to have latch clip engaging the door frame at three points on doors over 42" high and two points on all other doors. Locking device to be positive, automatic type, whereby locker door may be locked when open, then closed without unlocking. One rubber silencer shall be firmly secured in the frame at each heavy gauge latch hook. Latch clips shall be glass filled nylon for long life and low friction and shall hold doors shut be engaging the latch hooks. The latch channel assemble shall be quieted by the use of unique nylon glides to reduce noise. Door Handle & Latching 3 to 6 Tier Box Lockers: Doors shall be punched for use with padlocks or built-in locks. Doors for use with padlocks shall be equipped with an 18 gauge combination door pull, staple and lock hole cover plate with integral friction catch. |
Number Plates: Each locker to be supplied with a polished aluminum number plate, 2-1/4" wide x 1" high, with black etched numerals not less than 3/8" high. Number plates shall be attached to the face of the door with two aluminum rivets. Interior Equipment: Single-tier lockers 60" or higher shall have a hat shelf located approximately 9" below the top locker; if less than 18" deep, locker shall have three single-prong hooks and one double-prong ceiling hook. Single tier lockers 18" or more in depth shall have a coat rod instead of ceiling hook. 30" & 36" high lockers shall have three single-prong wall hooks and one double-prong ceiling hook. Hooks to be attached with two bolts per hook. 20" & 24" high lockers to have three wall hooks for 12" wide, and four wall hooks for 15" wide and wider.
Options
Recessed Handle 1,
2 & 3 Tier Latching: Delete the standard handle and provide handles recessed
in the door with finger lift control. 20 gauge drawn pocket shall be brushed stainless
steel securely fastened to the door with two tabs plus a positive tamper resistant
decorative fastener. The pocket shall be of sufficient depth to prevent a combination
padlock, built-in combination lock or key lock from protruding beyond the face of the
door. A lock hole cover plate shall be provided for sue with padlocks. Hush Tone Sound- Dampening Panels: Panels are designed to reduce sound levels when doors are slammed. They are 22 gauge and are die formed and have a full perimeter flange spot welded flush to the inside door surface and contain sound dampening material. Louvers are not used when sound-dampening panels are provided. Side and Back Ventilation: Sides and/or backs shall be perforated with 1/2" diameter holes in patterns of 42 holes per group.
Door Ventilation:
visual perforations shall consist of 5/8" wide x 1-1/8" high rectangular
perforations in the door in standard manufacturer's patterns. Doors with visual
perforations shall not have louvers. ADA Compliant Lockers: Handicap lockers shall have recessed handles and shall be single tier or the lower opening of a double tier locker. Locker bottom shall be a minimum of 9" off the floor, or an extra shelf placed 9" off the floor. Single tier lockers shall have a shelf 48" off the floor. Doors assigned for handicapped use shall have an appropriate symbol sign.
Execution Anchor Lockers to the floor and wall 48" on center or less as recommended by the manufacturer. Install Sloping Hoods and Metal Fillers using concealed fasteners. Provide flush hairline joints against adjacent surfaces. Install Benches by fastening bench tops to pedestals and securely anchoring to the floor using appropriate anchors for the floor material. Adjust & Clean: Adjust doors and latches to operate without binding. Verify that latches are operating satisfactorily. Touch Up marred finishes with factory supplied paint. If you have any other questions in regards to the specifications of our lockers, please call us at 1-800-881-1885 or send us an email through our Contact Us page. |
|
|